ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler

    Buy cheap ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler from wholesalers
     
    Buy cheap ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler from wholesalers
    • Buy cheap ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler from wholesalers
    • Buy cheap ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler from wholesalers

    ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler

    Ask Lasest Price
    Brand Name : ZL
    Model Number : ZL-5065
    Certification : CE,ISO
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 60 Sets
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler

    ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-level Sampler


    Product Overview:


    Bacteria filter efficiency [BFE] tester is developed based on the international advanced design concept of similar equipment, based on YY 0469-2011, YY / T 0969-2013 and other standards. It is mainly used for metrology verification departments, scientific research institutes, medical Mask production unit and its related testing department test the performance of mask bacterial filtration efficiency. It has the characteristics of fast and accurate measurement of the bacterial filtration efficiency [BFE] of the mask. It is equipped with a bioaerosol generator and two Anderson 6-level samplers, which meet the requirements of ASTM F2100, ASTM F2101, EN14683 and other standards.


    Mask Bacteria Filtration Efficiency [BFE] The tester adopts advanced technology and industrial computer control. The design friendly user interface and operation method make the user test simplified and easy to operate. The test results are displayed directly and are convenient and intuitive.


    Product Principle:


    By aerosol generating system, aerosol chamber and aerosol transmission device, negative pressure cabinet, 28.3L / min


    Sampler, etc., the entire detector is controlled by the console. The console uses a microcomputer control system to coordinate and control the work of the aerosol generation system, transmission system, negative pressure cabinet, and sampling system, and displays the working status in real time. The entire measurement work is automatically completed.


    Features:


    • The Mask bacterial filtration efficiency detector uses a negative pressure test system to ensure the safety of the operator;
    • Measurement system, built-in liquid supply system, equipped with I, II two-level 6-level Anderson sampling system;
    • The flow rate of the peristaltic pump can be set according to specific conditions;
    • The microbial aerosol generator bacterial liquid mist flow size can be adjusted and set, and the atomization effect is good;
    • Control system adopts PLC + LabView control, high-intensity color touch screen 10 inches, USB interface, supports U disk data transfer;
    • Built-in high-brightness lighting lamp, convenient for observation;
    • All flow control adopts mass flow control system;
    • Front glass door is convenient for the operator to observe the experiment process;

    Standards:


    • YY0469 Mask bacterial filtration efficiency [BFE] detection standard
    • YY / T 0969-2013 Standard for disposable medical masks
    • ASTM F2100 medical mask material performance specifications
    • ASTM F2101 Standard evaluation method for evaluating the bacterial filtration efficiency of medical mask materials using the bioaerosol of Staphylococcus aureus;
    • EN14683 medical mask requirements and test methods

    Technical parameter


    Mask Bacteria Filtration Efficiency Tester
    ModelZL-5065
    Vacuum pump

    Oil-free rotary vane vacuum pump, Maximum flow up to 57LPM,

    Equipped with silencer; stable airflow

    Aerosol generator flow control


    adopts mass flow control and the control is accurate.
    I Pneumatic sampling flow rateAnderson sampling flow rate 28.3L/min, Resolution:0.1L/min (User calibratable)
    II Pneumatic sampling flow rateAnderson sampling flow rate 28.3L/min Resolution: 0.1L/min (User calibratable)
    I & II sampling channelsEquipped with mass flow controller
    I Pneumatic pressure0-5kPa
    II Pneumatic pressure0-5kPa

    Spray flowmeter pressure0~120Pa
    The negative pressure of the aerosol chamberconforms to JJF1190-2008
    Working temperature0~50℃
    Cabinet negative pressure0~ 120Pa
    Data storage abilitycan download data through U disk
    Mass flow controller0~ 20L/min, resolution: 0.1L/min
    Peristaltic pump flow(0.01~3.0)mL/min
    High efficiency air filter characteristicsFiltration efficiency of particles above 0.3um≥99.99%

    Aerosol generator quality

    Median diameter

    Average particle diameter(3.0±0.3)μm,

    Geometric standard deviation≤1.5

    Two-way 6-level Anderson sampler captures particle size

    Ⅰlevel> 7μ m, Ⅱlevel(4.7~ 7)μm,

    Ⅲ level(3.3~ 4.7)μm, Ⅳ level(2.1~ 3.3)μm,

    Ⅴ level(1.1~2.1)μm, Ⅵ level(0.6~ 1.1)μm


    Aerosol chamber specifications


    600mm×80mm×5mm[L*D*T]

    Positive quality control Sampler particles

    Total

    (2200±500)cfu
    Ventilation flow of negative pressure system800m3/min
    Operating room sizeL 740×W 940×D 440 mm
    Dimensionsabout (L 1200 × W 650 × H 2100) mm
    Working power supplyAC 220V,50Hz
    Instrument noise<65dB(A)
    Weight120Kg
    Total power consumption<1500W

    Warranty


    1 year

    Accessories


    Aerosol generator 1 set
    Glass mixing chamber 1 set
    Anderson 6-level biological aerosol sampler 2 sets
    Sampling pump 2 sets
    Test tube rack 1 pc

    Quality ASTM F2101 Mask Bacteria Filtration Efficiency Tester With Dual 6-Level Sampler for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Zhongli Instrument Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)